{"id":468,"date":"2020-12-20T20:52:56","date_gmt":"2020-12-20T17:52:56","guid":{"rendered":"https:\/\/www.asilsanmuhendislik.com.tr\/?p=468"},"modified":"2023-08-23T12:13:12","modified_gmt":"2023-08-23T09:13:12","slug":"exproof-koruma-tipleri","status":"publish","type":"post","link":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/exproof-koruma-tipleri\/","title":{"rendered":"Exproof Koruma Tipleri"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">Exproof\u2019u \u00f6zellikle i\u015f sahalar\u0131 i\u00e7erisinde patlama ve yan\u0131c\u0131 riskinin y\u00fcksek oldu\u011fu alanlarda duymaktay\u0131z. Olas\u0131 riskleri ortadan kald\u0131rmak veya hasar\u0131 en aza indirmek i\u00e7in \u00e7al\u0131\u015fan exproof \u00fcr\u00fcnleri, kendi i\u00e7erisinde belirli s\u0131n\u0131flara ayr\u0131l\u0131r. Bu da \u00fcr\u00fcnlerin kullan\u0131laca\u011f\u0131 alanlar\u0131n tehlike ve risk durumlar\u0131na g\u00f6re belli olur. Exproof Koruma Tipleri de alanlar\u0131n sahip oldu\u011fu tehlike durumlar\u0131na g\u00f6re farkl\u0131 tasar\u0131m, de\u011fer ve \u015fekillerde \u00fcretilen \u00e7e\u015fitliliktedir.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u00dcr\u00fcnlerin \u00f6nleyici \u00f6zelli\u011fi, tehlike yaratacak unsurlar\u0131n bir araya gelmesini engeller. Bunlar, gaz, s\u0131v\u0131 veya buhar gibi yak\u0131tlar ile k\u0131v\u0131lc\u0131m, patlama, yang\u0131nlardaki ate\u015fleme ve oksijendir. Bu \u00fc\u00e7\u00fcn\u00fcn bir araya gelmesini engelleyen bu koruma tipleri de ortam \u00f6zelliklerine g\u00f6re s\u0131n\u0131fland\u0131r\u0131l\u0131r. \u00c7\u00fcnk\u00fc her \u00fcretim sahas\u0131ndaki tehlike riski ve oran\u0131 farkl\u0131d\u0131r. <strong>Exproof koruma tipleri<\/strong> a\u015fa\u011f\u0131daki gibidir ;<\/span><\/p>\n\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Ex 'i'<\/td><td class=\"column-2\">Kendinden Emniyetlilik<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Ex 'o'<\/td><td class=\"column-2\">Ya\u011fa Dald\u0131rma<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Ex 'n'<\/td><td class=\"column-2\">Normal \u00c7al\u0131\u015fma<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Ex 'm'<\/td><td class=\"column-2\">Kaps\u00fclleme<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Ex 'p'<\/td><td class=\"column-2\">Bas\u0131n\u00e7land\u0131rma<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Ex 'e'<\/td><td class=\"column-2\">Artt\u0131r\u0131lm\u0131\u015f G\u00fcvenlik<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Ex 'q'<\/td><td class=\"column-2\">Toz Doldurma<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-2 from cache -->\n<h2><span style=\"font-weight: 400;\">Exproof Tehlikeli B\u00f6lgelerin S\u0131n\u0131fland\u0131r\u0131lmas\u0131<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">\u00dcretim ve \u00e7al\u0131\u015fma sahalar\u0131n\u0131n kiminde s\u00fcrekli bir patlay\u0131c\u0131 risk olabilir. Kimilerinde ara ara bu risk olu\u015furken baz\u0131lar\u0131nda hi\u00e7 olmayabilir. Ancak tedbirler de olas\u0131 durumlara g\u00f6re al\u0131n\u0131r. Exproof \u00fcr\u00fcnlerinin kullan\u0131laca\u011f\u0131 alanlar\u0131n tehlikeli b\u00f6lge s\u0131n\u0131fland\u0131r\u0131lmas\u0131nda Zone b\u00f6lgesi esas al\u0131n\u0131r. Zone b\u00f6lgesi ne demek? sorusunu ise yukar\u0131da bahsedilen s\u00fcrekli patlama riskinin oldu\u011fu, riskin ara ara oldu\u011fu alanlar i\u00e7in b\u00f6yle bir isim verilir. Tedbirler de buna g\u00f6re al\u0131n\u0131r. Gaz ve buhar gibi maddelerde b\u00f6lge s\u0131n\u0131fland\u0131rmalar\u0131 \u015f\u00f6yle olur;<\/span><\/p>\n<ul>\n<li><b>Zone 0:<\/b><span style=\"font-weight: 400;\"> Patlay\u0131c\u0131 gazlar\u0131n y\u00fcksek oranda bulundu\u011fu b\u00f6lgeleri ifade eder. ISG B\u00f6lge 0 olarak da bilinir. Genelde buna \u00f6rnek olarak yak\u0131t tanklar\u0131 verilir.<\/span><\/li>\n<li aria-level=\"1\"><b>Zone 1:<\/b><span style=\"font-weight: 400;\"> Ayn\u0131 \u015fekilde y\u00fcksek oranda patlay\u0131c\u0131 gazlar olmas\u0131n\u0131n sadece tamir veya bak\u0131m gibi i\u015flemler s\u0131ras\u0131nda oldu\u011funu ifade eder. Benzin istasyonlar\u0131ndaki yak\u0131t pompalar\u0131 bu s\u0131n\u0131fa \u00f6rnek g\u00f6sterilebilir.<\/span><\/li>\n<li aria-level=\"1\"><b>Zone 2: <\/b><span style=\"font-weight: 400;\">Patlay\u0131c\u0131 riskinin y\u00fcksek oldu\u011fu buhar ve gazlar\u0131n k\u0131sa s\u00fcreli olarak yer ald\u0131\u011f\u0131 b\u00f6lgeyi ifade eder.\u00a0<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Tozlar ve lifler i\u00e7in ise tehlikeli b\u00f6lgelerin s\u0131n\u0131fland\u0131r\u0131lmas\u0131 \u015funlarla yap\u0131l\u0131r;<\/span><b><\/b><\/p>\n<ul>\n<li aria-level=\"1\"><b>Zone 20: <\/b><span style=\"font-weight: 400;\">Patlay\u0131c\u0131 riskinin y\u00fcksek oldu\u011fu toz ve liflerin ortamda s\u00fcrekli bulundu\u011fu alanlar\u0131 belirtir.<\/span><\/li>\n<\/ul>\n<ul>\n<li aria-level=\"1\"><b>Zone 21: <\/b><span style=\"font-weight: 400;\">Patlama riskinin y\u00fcksek oldu\u011fu liflerin, tozlar\u0131n ortamda bulunma ihtimalinin az oldu\u011fu alanlar\u0131 ifade eder.<\/span><\/li>\n<li aria-level=\"1\"><b>Zone 22: <\/b><span style=\"font-weight: 400;\">Tozlar\u0131n ve liflerin ortamda k\u0131sa s\u00fcre olarak bulunmas\u0131n\u0131 ifade eder.\u00a0<\/span><\/li>\n<\/ul>\n<p>Tavsiye \u0130\u00e7erik : <a href=\"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/exproof-lamba-nedir\/\"><strong>Exproof Lamba<\/strong><\/a><\/p>\n<h2><span style=\"font-weight: 400;\">Exproof Cihazlar\u0131n\u0131n S\u0131n\u0131fland\u0131r\u0131lmas\u0131<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Yanma ve patlama riskine kar\u015f\u0131 koruyucu \u00f6zelli\u011fi bulunan exproof cihazlarda da belirli bir s\u0131n\u0131fland\u0131rma s\u00f6z konusudur. Burada ise genel anlamda maden ocaklar\u0131nda kullan\u0131lan grup 1 ile di\u011fer t\u00fcm cihazlar\u0131 kapsayan grup 2 ba\u015fl\u0131klar\u0131ndan s\u00f6z edebiliriz. Ancak cihazlar\u0131 patlay\u0131c\u0131 ve s\u0131cakl\u0131k \u00f6zelliklerine g\u00f6re de s\u0131n\u0131flara ay\u0131rmaktay\u0131z. Burada da D, E, P, \u0130, O, N, Q tipi koruma cihazlar\u0131n\u0131 g\u00f6rmekteyiz.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Burada da D tipi bas\u0131nca dayan\u0131kl\u0131d\u0131r. E tipi y\u00fcksek oranda alev s\u0131zd\u0131rmaz \u00f6zelli\u011fi ta\u015f\u0131r. P tipi ise patlay\u0131c\u0131 gaz\u0131 d\u0131\u015far\u0131da b\u0131rakan bas\u0131n\u00e7 dayan\u0131kl\u0131 \u00f6zellik g\u00f6sterir. \u0130 tipi korumada ise kendinde koruma g\u00f6r\u00fcl\u00fcr, sistemdeki elektrikli aletlerin tamam\u0131 kendinden emniyetli olur. O tipinde ise ya\u011fa dald\u0131rma tekni\u011fi vard\u0131r, par\u00e7alar \u00fczerindeki ya\u011flar\u0131n ate\u015flenmemesini ifade eder. N tipinde de s\u0131zd\u0131rmaz koruma g\u00f6r\u00fcl\u00fcr. M tipinde patlay\u0131c\u0131 ortamda ate\u015flenebilecek cihazlar\u0131n bile\u015fi\u011fi yerle\u015ftirilmesi vard\u0131r. Ve son olarak Q tipinde ise tutu\u015fma kayna\u011f\u0131 kuma dald\u0131r\u0131l\u0131 ve patlay\u0131c\u0131 gaz d\u0131\u015far\u0131da olur.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Exproof\u2019u \u00f6zellikle i\u015f sahalar\u0131 i\u00e7erisinde patlama ve yan\u0131c\u0131 riskinin y\u00fcksek oldu\u011fu alanlarda duymaktay\u0131z. Olas\u0131 riskleri ortadan kald\u0131rmak veya hasar\u0131 en aza indirmek i\u00e7in \u00e7al\u0131\u015fan exproof \u00fcr\u00fcnleri, kendi i\u00e7erisinde belirli s\u0131n\u0131flara ayr\u0131l\u0131r. Bu da \u00fcr\u00fcnlerin kullan\u0131laca\u011f\u0131 alanlar\u0131n tehlike ve risk durumlar\u0131na g\u00f6re belli olur. Exproof Koruma Tipleri de alanlar\u0131n sahip oldu\u011fu tehlike durumlar\u0131na g\u00f6re farkl\u0131 tasar\u0131m, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-468","post","type-post","status-publish","format-standard","hentry","category-genel"],"_links":{"self":[{"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/posts\/468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/comments?post=468"}],"version-history":[{"count":4,"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/posts\/468\/revisions"}],"predecessor-version":[{"id":901,"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/posts\/468\/revisions\/901"}],"wp:attachment":[{"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/media?parent=468"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/categories?post=468"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.asilsanmuhendislik.com.tr\/uk\/wp-json\/wp\/v2\/tags?post=468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}